FREE SHIPPING ITEM

30 DAYS FREE RETURN

CASH ON DELIVERY

Meg Medius

Cart

PATIENT MONITOR LTP001

5,000.00

Availability: Out of stock

E CG
Input: 5 wires ECG cable
Lead section:Ⅰ,Ⅱ,Ⅲ/ aVR, aVL, aVF/ V
Gain(mm/mV): 1/4,1/2,1,2,4
Sweep speed(mm/sec): 6.25,12.5, 25, 50
Heart rate range: 15-300 BPMHeart rate accuracy: ± 1 %

Out of stock

SKU: PMT01 Category:
Spread the love
1. Displayer:15″ color TFT LCD screen with multi-channel waveform display.
2. Battery: Rechargeable high-energy built-in battery

3.  Advanced streamline outline design, portable, compact, lightweight 

4. Operating menu with multi-language interface selection: English, Spanish, Portuguese, Chinese, Arabic, Russian, Italian, etc.

5.Easy operation with user friendly menu structure design and rotary dial 

6.Remote control ability for long distance operation.

7.Against & eliminate ESU interference & defibrillation, no need to disconnect the monitor from the patient in process of defibrillating.

8.Three-application mode: monitoring, diagnosis, operating.

9. WAN communication function to network with central monitoring system and make long-distance monitoring, diagnosis, maintenance and software upgrade possible

10.Optional built-in wireless networking function 

11.360 hours data storage.

12. With Drug dose calculation function

13. Intelligent audio and visual comprehensive alarm

14.In-hospital applications include emergency room’s pre and post operative care, ICU, Operation room/theater, ambulatory surgery, intermediate care/step down units, labor and delivery, and hospital-based special procedure areas.

15.Suitable for use in physicians’ offices, clinics, outpatient surgical centers, extended care facilities and other patient care areas, which of require affordable monitoring.
16.Suitable for adult, pediatrics, neonates
 
E CG

Input: 5 wires ECG cable 

Lead section:
,,/ aVR, aVL, aVF/ V 

Gain
mm/mV: 1/4,1/2,1,2,4

Sweep speed(mm/sec): 6.25,12.5, 25, 50 

Heart rate range: 15-300 BPM
Heart rate accuracy: ± 1 %

ST segment deviation analysis
NIBP (Non-invasive blood pressure) ()
Measurement type : adult, pediatric, neonatal 

Measurement range: Systolic
  4.0 – 37.0 kPa 

                          Diastolic   1.3 – 33.0 kPa 

                         Mean        2.6 – 35.0 kPa

Accuracy : ± 0.4 kPa or 5 %

Resolution: 0.1 kPa
Protection: over pressure
Tourniquet function
 
Temperature (surface and rectal)

Measurement range: 25.0 – 45.0 

Accuracy: ± 0.1 

Resolution: 0.1 

response time: ≤ 3 min.
 
Respiration Rate(RA-LL,RA-LA,LL-LA selectable impedance and nasal cavity) 

Measurement range: 0 – 120 BPM

Accuracy: ± 1 BPM or 5 %

Resolution: 1 BPM
Pulse RateSPO2 measurement range: 0 – 100 %

Resolution: 1 %

Pulse measurement range: 30- 250BPM

Accuracy: ± 2 %

Resolution: 1 BPM
 
IBP(Invasive blood pressure) (Option)Measurement range: -1.3~40kPa (-10~300mmHg) 

Channel: 4 channel

Transducer sensitivity: 5MV/V/mmHg 

Unit display: KPa or mmHg selectable
 
ETCO2 (main/side stream type) (Option) – Plug&PlayMeasurement range:0 – 150 mmHg 0 – 19.7% 0 – 20kpa
(Barometric pressure supplied by Host)

Accuracy: 0- 40 mmHg 
± 2mmHg
 41-70 mmHg ±5% of reading
 71-100mmHg±8% of reading
 101-150mmHg±10% of reading
Above 80 breath per minute±12% of reading
*NOTE: Gas temperature at 25 
Sample rate:50ml/minResponse time:< 3 seconds – includes transport time and rise time                
 
Cardiac Output Option
Meathod: thermodilution
Measurement range: CO:0.1-20.0 L/min
                               TB:23 – 43 
TI:0 – 27 
 Resolution:             CO:0.1 L/min
                              TI:0.1 
                              TB:0.1 
 Accuracy:              CO: ± 0.2 L/min or ±5%
                             TB: ± 0.2 
                             TI: ± 0.2 
Parameter output:
Cardiac output Hemodynamics calculation
  Power requirements 

  Input:  100240 V AC,  50/60Hz

  Consumption:    ≤ 80VA

  Environment

 
        Operation            Storage

  Temperature         0.5 – 40 
          -20 – 50 

  Relative humidity  ≤ 80%
Safety standard: IEC 60601-1
Quality System: ISO13485: 2003

 

Reviews

There are no reviews yet.

Be the first to review “PATIENT MONITOR LTP001”

Your email address will not be published. Required fields are marked *

Loading...
Back Top